| QUALITÉ |
PRINTFLOOR ® |
CLINICFLOOR ® |
| VERSION |
AXA |
AXS |
SAI - AXA |
SAI - AXS |
| SURFACE: COMPOSITION DE LA FIBRE /
SECTION DE LA FIBRE |
PA6.6/0.01 |
PA6.6/0.01 |
PA6.6/0.01 |
PA6.6/0.01 |
| DÉNOMINATION COMMERCIALE DE LA FIBRE |
 |
 |
 |
 |
| SOUS-COUCHE: QUALITÉ DE LA FIBRE |
100% Polyestere |
100% Polyestere |
100% Polyestere |
100% Polyestere |
| SUPPORT: QUALITÉ |
fibre |
mousse latex |
fibre |
mousse latex |
| DÉNOMINATION COMMERCIALE DU SUPPORT |
|
 |
|
 |
| POIDS: COUCHE D'USURE DIN 54325
SUPPORT
TOTAL DIN 53854 |
900 GR/M2
-
900 GR/M2 |
900 GR/M2
700 GR/M2
1600 GR/M2 |
940 GR/M2
-
940 GR/M2 |
940 GR/M2
700 GR/M2
1640 GR/M2 |
| EPAISSEUR: COUCHE D'USURE DIN 54325
TOTAL DIN 54855 |
1.7 MM
3.5 MM |
1.7 MM
5.5 MM |
1.7 MM
3.5 MM |
1.7 MM
5.5 MM |
| DIMENSIONS: ROULEAUX DIN 53851 |
2 x 50 M |
2 x 30 M |
2 x 50 M |
2 x 30 M |
| PLINTHE: LARGEUR |
8 CM |
- |
8 CM |
- |
| SOLIDITÉ COULEURS RÉSISTANCE À
LA LUMIÉRE DIN 54004
RÉSISTANCE À L'EAU DIN 54006
RÉSISTANCE AU FROTTEMENT SEC DIN 54021
RÉSISTANCE AU FROTTEMENT HUMIDE DIN 54021 |
6 - 7
4 - 5
5
4 - 5 |
6 - 7
4 - 5
5
4 - 5 |
6 - 7
4 - 5
5
4 - 5 |
6 - 7
4 - 5
5
4 - 5 |
| CARACTÉRISTIQUES ELECTRIQUES DIN
54345 POTENTIEL 23 C 25% UR
Electrostatique Semelle de PVC
Semelle de MOUSSE
Semelle de NEOLITE
Resistance Verticale
Resistance Horizontale
METHODE B.C.T.C. P2T1/10-13 |
<= 2 Kv
< 1010 Ohms cm2
-
-
- |
<= 2 Kv
-
-
-
-
- |
-
< 1.6 Kv
< 1.5 Kv
< 1.7 Kv
< 10 ohms
< 10 ohms |
-
< 1.6 Kv
< 1.5 Kv
< 1.7 Kv
< 10 ohms
< 10 ohms |
| RÉACTION AU FEU |
M3 - BK2 V2 CLASSE 1 |
M3 - BK2 V2 CLASSE 1 |
M3 - BK2 V2 CLASSE 1 |
M3 - BK2 V2 CLASSE 1 |
| RÉSISTANCE THERMIQUE: DIN 52612 |
0.08 M2 C/W |
0.09 M2 C/W |
0.09 M2 C/W |
0.09 M2 C/W |
| ABSORPTION ACOUSTIQUE: DIN 52210 |
21 dB |
25 dB |
21 dB |
25 dB |
| TRAITEMENTS: SANIBAC ® -
ANTISALISSURE
- ANTIMICROBIEN
- HYDROFUGE: METHODE B.C.T.C.P2T1/15 |
-
-
- |
-
-
- |
 
RESINE |
 
RESINE |
| DÉTERMIN. DES EFFETS DE L'EAU DE JAVEL ET DE L'
ANTISEPTIQUE: METHODE P2T1/15 1=CHANGEMENT
TRÈS MARQUÉS
5=AUCUN CHANGEMENT |
- |
- |
4 + 3 |
4 + 3 |
| EVALUATION DE LA SURVIE DES MICRO-ORGANISMES: METHODE P2T1/19 APRÈS 24 h |
- |
- |
0 |
0 |
| DÉTERMIN. DE LA FACILITÉ D'ENLÈVEMENT DES PROTEINES
(SANG): METHODE B.C.T.C. P2T1/20 APRÈS 5
minutes:
APRÈS 24 h: |
-
- |
-
- |
99.4%
99.3% |
99.4%
99.3% |
| DÉTERMIN. DE LA FACILITÉ D'ENLÈVEMENT DE L'URINE: METHODE B.C.T.C. P2T1/21 APRÈS 5 minutes:
APRÈS 24 h: |
-
- |
-
- |
100%
95% |
100%
95% |
| DÉTERMIN. DU FACTEUR DE RESISTANCE AU TRAFFIC A
ROULETTES(Roulette Ø 75mm) METHODE B.C.T.C. P2T1/18
LIGNE DROITE:
ANGLE DROITE: |
-
- |
-
- |
1.48 Kg
1.81 Kg |
1.48 Kg
1.81 KG |
| CERTIFICATION EUROPEENNE EN1470 |
CLASSE 4 = TRAFIC INTENS |
| EMISSIONS TOXIQUES: TESTS EFFECTUÉS
CHEZ L'INSTITUT CANADIENNE ORTECH |
LE PRODUIT A SATISFAIT LE TEST
DE NON EMISSION TOXIQUE ASTM D5116-90 (USA) |
| POSE |
COLLÈE |
COLLÈE |
COLLÈE |
COLLÈE |
| INFORMATIONS À TITRE INDICATIF, SUSCEPTIBLES
D'ETRE MODIFIEES |